{"product_id":"residual-current-circuit-breaker-rccb-elcb-double-pole","title":"Residual Current Circuit Breaker (RCCB\/ELCB) Double Pole","description":"\u003ch2\u003eResidual Current Circuit Breaker (RCCB \/ ELCB) — Double Pole\u003c\/h2\u003e\n\u003cp\u003eKeep your home and equipment safe from dangerous earth‑leak faults with the \u003cstrong\u003eH‑RCCB‑ELCB‑DP\u003c\/strong\u003e — a compact, high‑safety double‑pole residual current breaker designed to detect leakage currents and cut power before harm occurs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick takeaway\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003edouble‑pole RCCB\u003c\/strong\u003e instantly disconnects both live and neutral on detecting imbalance between phases, preventing \u003cstrong\u003eelectric shock\u003c\/strong\u003e, \u003cstrong\u003efire risk from earth leakage\u003c\/strong\u003e, and damage to sensitive appliances. This listing shows \u003cstrong\u003e25A\u003c\/strong\u003e models with \u003cstrong\u003e30mA or 100mA\u003c\/strong\u003e trip sensitivity options — choose lower mA for personal protection (sockets, bathrooms) and higher mA for selective appliance protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat it does\u003c\/h2\u003e\n\u003cp\u003eRCCBs monitor current flow in live and neutral conductors. If a difference (residual current) appears — indicating current is leaking to earth — the device \u003cstrong\u003etrips immediately\u003c\/strong\u003e, isolating the circuit and reducing the risk of electrocution or insulation‑fault fires. The double‑pole design ensures both conductors are disconnected for maximum safety.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble‑pole protection\u003c\/strong\u003e — isolates both live and neutral together for safer disconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable sensitivities — 30mA \/ 100mA\u003c\/strong\u003e — \u003cstrong\u003e30mA\u003c\/strong\u003e for human protection, \u003cstrong\u003e100mA\u003c\/strong\u003e for equipment\/earth‑fault selectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated example — 25A\u003c\/strong\u003e (check the product page for available ampere ratings).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast, reliable trip action\u003c\/strong\u003e — reduces shock and fire risk from leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact wall\/DB mount form\u003c\/strong\u003e — fits consumer units and distribution boards for neat installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand-grade construction\u003c\/strong\u003e — built for consistent operation in residential and light‑commercial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy this RCCB stands out\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife‑saving protection\u003c\/strong\u003e — a 30mA RCCB cuts fault current fast enough to prevent serious electric shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced fire risk\u003c\/strong\u003e — detects small leakages that ordinary MCBs won’t catch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible selection\u003c\/strong\u003e — sensitivity options let you match protection to the circuit (personal vs. device).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple upgrade\u003c\/strong\u003e — an easy way to bring older installations up to safer standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear peace of mind\u003c\/strong\u003e — reliable residual‑current monitoring for kitchens, bathrooms, outdoor sockets, and workshops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSocket circuits and general household protection\u003c\/li\u003e\n\u003cli\u003eBathroom and kitchen outlets (where water increases shock risk)\u003c\/li\u003e\n\u003cli\u003eOutdoor and garden power points\u003c\/li\u003e\n\u003cli\u003eBackup generator and inverter output protection\u003c\/li\u003e\n\u003cli\u003eWorkshops, garages, and light commercial circuits where leakage protection is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; note\u003c\/h2\u003e\n\u003cp\u003eFor correct selection and safe installation, confirm the required \u003cstrong\u003eampere rating\u003c\/strong\u003e and \u003cstrong\u003etrip sensitivity\u003c\/strong\u003e for each circuit — use \u003cstrong\u003e30mA\u003c\/strong\u003e for personal protection and \u003cstrong\u003e100mA\u003c\/strong\u003e where nuisance trips are a concern but some earth‑fault protection is still needed. Have a qualified electrician install and test the RCCB and, if available, consult the product datasheet for mounting and wiring details.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eReady to protect people and property? Choose the \u003cstrong\u003eH‑RCCB‑ELCB‑DP\u003c\/strong\u003e for \u003cstrong\u003efast, reliable earth‑leak detection, double‑pole isolation, and everyday peace of mind\u003c\/strong\u003e — add to cart to upgrade safety in minutes.\u003c\/p\u003e","brand":"Havells","offers":[{"title":"Default Title","offer_id":52643524247839,"sku":null,"price":500.0,"currency_code":"BDT","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/0639\/9519\/files\/113_8a10be69-a2a6-47cf-9277-e0eed047bb4b.png?v=1782581715","url":"https:\/\/www.alphaemart.shop\/products\/residual-current-circuit-breaker-rccb-elcb-double-pole","provider":"ALPHAEMART","version":"1.0","type":"link"}